Where Waveguide-to-Coax Transition Loss Comes From and How to Diagnose It
Millimetre-wave engineers often measure more insertion loss than a transition's spec sheet suggests, typically around 0.6 dB versus a quoted 0.3 dB. The article explains that a transition converts the TE10 mode in rectangular waveguide to the TEM mode in coaxial line over a length of roughly a quarter to half a wavelength. Loss depends on the frequency band chosen, the probe depth tolerance, and an inherent impedance step at the junction. Flange misalignment is highlighted as a common culprit that appears as mismatch ripple rather than absorption loss, and it can be detected by examining S11 and the periodicity of ripple in S21. The author, from DB Design, recommends alignment-pinned flanges, cross-pattern torquing, and checking band-edge loss and two-port return loss when evaluating parts.