SShortSingh.
Back to feed

Giving AI agents a browser without exposing your personal Chrome session

0
·4 views

The article argues that attaching an AI agent to a personal Chrome window over CDP is risky, since it exposes every logged-in account, cookies, and local network services. It notes that local headless browsers in fresh profiles tend to stall on logins, passkeys, or verification prompts with no clean way for a person to step in. The proposed alternative is a remote cloud browser that keeps the user's machine and local network isolated. Human handoff occurs through a live viewer link to that remote session, so people can complete sign-ins before the agent continues. The piece also recommends matching browser setup to task type, such as agent-only for public reads and live viewing for authenticated or approval-based work.

Read the full story at DEV Community

This is an AI-generated summary. ShortSingh links to the original source for the complete article.

Discussion (0)

Log in to join the discussion and vote.

Log in

Related stories

0
ProgrammingDEV Community ·

DDEV 1.25.4 and 1.25.5 add database seeding, global hooks and easier service restarts

A WordPress developer describes moving from Trellis, Bedrock and Sage to DDEV for local development, which manages the environment while other tools handle project layout and deployment. The DDEV updates released on September 2 and October 26 introduce features such as seeding a new database volume from a snapshot, resetting the database, restarting individual services, and running global hooks. Composer's lock file pins plugin versions for reproducible dependency installs, though it does not restore databases or uploads. The author also explains that the Site Editor depends on the theme type rather than the tooling, and notes that Trellis handles deployment with rollbacks while DDEV hosting remains experimental. The examples were checked against command help output but not run against a live project.

0
ProgrammingDEV Community ·

Distance vs displacement: handling zero-velocity crossings in JavaScript

A physics graphing widget can report correct displacement yet an incorrect distance if each trapezoid's absolute value is taken when the interval crosses zero velocity. Area above and below the axis cancels within such a trapezoid, hiding the true distance. The article illustrates this with a 4-second interval moving from +3 m/s to −1 m/s, where displacement is 4 m but distance is 5 m. It presents a JavaScript function that splits crossing segments at the zero point and sums the two parts separately. Summing signed displacements and unsigned distances across sampled points yields exact results for piecewise-linear graphs, though curved segments only give approximations.

0
ProgrammingDEV Community ·

Keeping Cursor, Claude Code and Copilot on one set of team rules

A team using Cursor, Claude Code, Copilot and a nightly Codex job found that each agent followed a different instruction file, leading to conflicting designs for the same ticket. The proposed fix is to store all coding rules once in a repository directory, named .ai-lint/, and turn each agent's instruction file into a short pointer to it. Rules carry IDs so agents can cite them and reviewers can check compliance, and a four-field override block lets people break a rule deliberately with a visible record. Teams are advised to test wiring by sending each agent a request that violates a rule, and to update rules in the same commit as the code they describe. Rules should be kept short, current, and reviewed like any other code.

0
ProgrammingDEV Community ·

Why ESP32 ADC voltage readings vary: calibration and configuration explained

Espressif's ESP-IDF documentation explains that ESP32 analog readings depend on the chip's reference voltage, which is nominally 1100 mV but can range from 1000 mV to 1200 mV between chips. The calibration driver uses eFuse-stored parameters where available, and falls back to an estimated default reference when none are burned. The oneshot driver requires attenuation and bit width to be set per channel and matched in the calibration scheme. The docs also warn that adc_oneshot_read() must be called from a task rather than an interrupt, and that ADC2 is shared with Wi-Fi. The review concludes that absolute voltage accuracy requires calibration and checking the board's calibration source.